Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 320
Filtrar
1.
Med Mycol ; 59(7): 672-682, 2021 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-33330930

RESUMO

Histoplasma antigen detection in urine is a rapid diagnostic method for disseminated histoplasmosis, although cross-reactivity has been reported in specimens from patients with other thermally dimorphic fungal infections. We tested urine specimens, from persons with suspected invasive fungal infections, using a commercial monoclonal antibody Histoplasma enzyme immunoassay (EIA) at a South African national mycology reference laboratory from August 2014 through December 2018. Corresponding fungal culture and histopathology results were obtained from an electronic laboratory information system. In some cases, cultured fungal isolates were sent with the urine specimen for species-level identification by phenotypic and molecular methods. Cross-reactivity was confirmed using culture filtrates of several fungal pathogens. Of 212 referred cases, 41 (19%) were excluded since they had no recorded clinical history (n = 1), alternative diagnoses were confirmed (n = 2), or no fungal culture or histopathology results (n = 38). Eighty-seven of 212 (41%) had laboratory evidence of an invasive fungal disease, while 84 (40%) did not. Of the 87 cases, 37 (43%) were culture-confirmed mycoses: emergomycosis (n = 18), histoplasmosis (n = 8), sporotrichosis (n = 6), cryptococcosis (n = 2), talaromycosis (n = 1), and other fungi isolated (n = 2). The sensitivity and specificity of the EIA were calculated for two groups: culture-confirmed (n = 37) and histology-confirmed invasive fungal disease (n = 50). The sensitivity and specificity of the EIA for diagnosis of histoplasmosis compared to culture were 88% (7/8, 95%CI 47-100%) and 72% (21/29, 95%CI 53-87%), respectively, and for diagnosis of emergomycosis/histoplasmosis compared to histology was 83% (29/35, 95%CI 66-93%) and 93% (14/15, 95%CI 68-100%), respectively. Cross-reactions occurred in urine specimens of patients with Emergomyces africanus infection and in culture filtrates of E. africanus, T. marneffei and Blastomyces species. A commercial Histoplasma EIA had satisfactory accuracy for diagnosis of culture-confirmed histoplasmosis, but cross-reacted in urine specimens from patients with invasive disease caused by the closely-related pathogen, E. africanus and in culture filtrates of E. africanus and other related fungi. LAY SUMMARY: Emergomyces africanus and Histoplasma capsulatum are fungi that cause a multi-system disease among HIV-seropositive persons with a low CD4 cell count. Handling live cultures of these fungi to confirm a diagnosis requires specialized laboratory equipment and infrastructure which is infrequently accessible in low-resource settings. The features of the two diseases (i.e., disseminated histoplasmosis and emergomycosis) may be indistinguishable when infected tissue is prepared, stained, and examined under a microscope. Enzyme immunoassays (EIA) have been developed as rapid diagnostic tools for the detection of a cell wall component of H. capsulatum in urine specimens, although cross-reactions have been reported in specimens from patients with other fungal infections. We evaluated the accuracy of a commercial Histoplasma EIA to diagnose histoplasmosis and to assess cross-reactions in urine specimens from persons with emergomycosis and in cultures of E. africanus and related fungi. We report a sensitivity and specificity of 88% (95%CI 47-100%) and 72% (95%CI 53-87%) for diagnosis of histoplasmosis compared to culture and 83% (95%CI 66-93%) and 93% (95%CI 68-100%) for diagnosis of either histoplasmosis/emergomycosis compared to a diagnosis made by microscopic examination of infected tissue. The assay cross-reacted in urine specimens from patients with emergomycosis and in culture filtrates of related fungi. Although the EIA cross-reacted with other related fungi, this test can decrease the time to diagnosis and facilitate early treatment of emergomycosis and histoplasmosis in South Africa.


Assuntos
Antígenos de Fungos/imunologia , Histoplasma/imunologia , Histoplasmose/urina , Técnicas Imunoenzimáticas/normas , Kit de Reagentes para Diagnóstico/normas , Adulto , Anticorpos Monoclonais/imunologia , Reações Cruzadas , Feminino , Histoplasma/química , Histoplasmose/diagnóstico , Histoplasmose/imunologia , Humanos , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Infecções Fúngicas Invasivas/diagnóstico , Infecções Fúngicas Invasivas/imunologia , Masculino , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , África do Sul
2.
J Clin Virol ; 111: 39-41, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30639846

RESUMO

BACKGROUND: Simplifying hepatitis C virus (HCV) screening is a key step in achieving the elimination of HCV as a global public health threat by 2030. OBJECTIVES: The objective of this study was to demonstrate the agreement of capillary blood and venipuncture specimens when using SD Bioline© HCV, a low-cost rapid diagnostic test (RDT), prequalified by WHO in 2016 on venous blood samples. STUDY DESIGN: Recruitment was conducted prospectively among adult patients presenting for HCV testing at the Médecins Sans Frontières (MSF) clinic of Preah Kossamak Hospital (Phnom Penh, Cambodia) between October and November 2017. Capillary and venous blood samples were collected from consenting patients and tested with SD Bioline© HCV. Two independent, blinded readers, and in the case of disagreement, a third reader, interpreted the results of each blood sample. Concordance between results was compared using Cohen's Kappa interrater reliability statistic. Discrepant sample pairs were tested with an enzyme immunoassay, the reference standard, at the Institute Pasteur of Cambodia. RESULTS: Among 421 pairs of samples collected, reader disagreement occurred for 0.7% (n = 3) of the participants. Sixty-four percent of capillary and venous blood sample pairs tested positive for HCV, with a Kappa statistic of 0.985 between the two methods. Three participants with discrepant sample pair results tested positive with EIA. CONCLUSIONS: Capillary and venous blood samples were concordant when tested with HCV SD Bioline© in a clinical context. This simplified testing approach is essential to the scale-up of HCV screening and useful in resource-limited settings or among populations for whom venipuncture is problematic.


Assuntos
Capilares , Anticorpos Anti-Hepatite C/sangue , Hepatite C/sangue , Hepatite C/diagnóstico , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Veias , Instituições de Assistência Ambulatorial , Camboja , Feminino , Hepacivirus/imunologia , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Flebotomia , Estudos Prospectivos , Reprodutibilidade dos Testes
3.
J Trop Pediatr ; 65(3): 210-216, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30007342

RESUMO

We aimed to evaluate in an Algerian pediatric population the diagnostic performances of the IDEIA HpStAR noninvasive stool antigen test (Oxoid, Cambridge, UK) to detect Helicobacter pylori infection before and after eradication therapy. A prospective study including 158 symptomatic Algerian children was conducted. Patients were initially diagnosed with invasive (culture, histology, and rapid urease test) and noninvasive tests (urea breath test and IDEIA HpStAR test). Infected patients were treated, and 101 were controlled after treatment with two invasive (culture and histology) and two noninvasive tests (urea breath test and IDEIA HpStAR test). In Algerian children, the IDEIA HpStAR test showed good performances for initial detection of H. pylori infection and also for subsequent control of eradication treatment. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of IDEIA HpStAR test before treatment were 93.6%, 100%, 100%, 87.3%, and 96%, respectively, and those after treatment were 100, 92.8, 78.6, 100, and 94.2%, respectively.


Assuntos
Antígenos de Bactérias/análise , Fezes/microbiologia , Infecções por Helicobacter/diagnóstico , Infecções por Helicobacter/microbiologia , Helicobacter pylori/isolamento & purificação , Técnicas Imunoenzimáticas/métodos , Argélia , Antibacterianos/uso terapêutico , Testes Respiratórios , Criança , Fezes/química , Feminino , Infecções por Helicobacter/tratamento farmacológico , Infecções por Helicobacter/imunologia , Helicobacter pylori/imunologia , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
4.
PLoS One ; 13(9): e0204001, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30212544

RESUMO

BACKGROUND: Although reverse sequence algorithms (RSA) for syphilis screening are performing well, they still have to rely on treponemal confirmatory tests at least for sera reactive by enzyme immunoassay/chemiluminescence immunoassay (EIA/CIA) and unreactive by rapid plasma reagin (RPR). Quebec's laboratory network previously showed that 3.3% of EIA/CIA reactive and weakly-reactive RPR samples (RPR titer of 1 to 4) would have been misclassified as syphilis cases if a treponemal confirmatory test had not been performed. OBJECTIVES: To correlate the magnitude of signal-to-cutoff (S/CO) ratios of the 4 most used commercial first-line EIA/CIA kits in Quebec with syphilis confirmation results and establish a S/CO value above which treponemal confirmation would not be required. METHODS: Serum samples from previously undiagnosed individuals (n = 7 404) obtained between January 2014 and February 2017 that were reactive by EIA/CIA and either negative by RPR or reactive with a low titer (1 to 4) were included in the study. All samples were tested with Treponema pallidum particle agglutination (TP-PA) and, if negative or inconclusive, with a line immunoassay (LIA). Syphilis infection confirmation was defined by a reactive TP-PA or LIA. Logistic regression analysis was used to determine S/CO values (95% CI lower bound = 0.98) above which confirmation would not be required. The four kits studied were Architect TP, BioPlex IgG, Syphilis EIA II, and Trep-Sure. RESULTS: Of 2609 reactive EIA/CIA specimens tested for the determination of S/CO values, 1730 (66%) were confirmed as true syphilis cases. Confirmation rate was significantly higher in samples with low-titer positive RPR (92%) than with negative RPR samples (54%); p<0.01. A linear probability model (95% CI lower bound = 0.98) predicted the S/CO value above which a confirmation would no longer be needed for the Architect TP (16.4), Bioplex IgG (7.4) and Trep-Sure (24.6). No linearity was observed between the S/CO value of Syphilis EIA II and the confirmation rate. The validity of the predicted S/CO values was investigated using 4 795 specimens. The use of an S/CO value of 16.4 with the Architect TP kit and of 24.6 for the Trep-Sure kit would obviate the need for confirmation of 18.5% and 13.2% of sera from the all RPR subgroup, respectively. For the BioPlex IgG kit, 81.1% of sera would not require confirmation when using the S/CO value of 7.4 in the low titer RPR subgroup. CONCLUSION: Signal-to-cut-off values could be used to identify sera that do not require extra treponemal confirmation for 3 of the 4 most used first-line EIA/CIA kits in Quebec. Using these values in our current reverse screening algorithm (RSA) would avoid the need for confirmatory tests in 14 to 20% of sera, a proportion that could reach 75% among low-titer RPR.


Assuntos
Sorodiagnóstico da Sífilis/métodos , Sífilis/diagnóstico , Algoritmos , Erros de Diagnóstico , Humanos , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Programas de Rastreamento/métodos , Programas de Rastreamento/estatística & dados numéricos , Quebeque , Razão Sinal-Ruído , Sorodiagnóstico da Sífilis/estatística & dados numéricos , Teste de Imobilização do Treponema/estatística & dados numéricos
5.
Arq. bras. med. vet. zootec. (Online) ; 70(3): 787-792, maio-jun. 2018. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-911354

RESUMO

A brucelose na espécie ovina tem recebido destaque, uma vez que se trata de uma enfermidade que acomete o sistema reprodutivo dos animais, provocando sério comprometimento no setor produtivo. Dessa forma, objetivou-se a avaliação de três métodos para o diagnóstico da brucelose ovina: o ensaio imunoenzimático indireto (ELISAi), a técnica imunodifusão em gel de ágar (IDGA) e a reação em cadeia da polimerase (PCR). Para tanto, utilizaram-se 211 amostras de sangue de ovinos oriundos de propriedades de nove municípios da microrregião homogênea de Teresina, Piauí. As 211 amostras de sangue foram submetidas aos testes sorológicos e à PCR, visando detectar anticorpos anti-B. ovis e DNA de Brucella ovis, respectivamente. Foram obtidos resultados positivos nos testes sorológicos, sendo 36 (17,06%) positivos no teste IDGA e sete (3,31%) positivos no teste ELISAi, contudo não houve resultados positivos na técnica de PCR. Dos métodos de diagnóstico utilizados neste estudo, o teste IDGA foi o que apresentou melhor desempenho na detecção de animais reagentes, quando comparado ao teste ELISAi e à PCR em amostras de sangue, e o percentual de animais soropositivos sugere uma ampla distribuição de ovinos infectados por Brucella ovis na região em estudo, o que pode causar prejuízos aos produtores.(AU)


Brucellosis in sheep has received a major focus, since it is a disease that affects the reproductive system of animals, causing serious impairment in the productive sector. Thus, three methods for the diagnosis of ovine brucellosis were evaluated as goal, the indirect Linked Immunosorbent Assay (ELISAi) test, the Immunodiffusion Agar Gel (AGID) technique and the Polymerase Chain Reaction (PCR). Therefore, we used 211 sheep blood samples from properties of nine municipalities of the homogeneous micro-region of Teresina, Piaui. The 211 blood samples were subjected to serologic testing and PCR to detect anti-B. ovis antibodies, and Brucella ovis DNA, respectively. Positive results in serological tests were obtained, 36 (17%) positive in the AGID test and seven (3.3%) positive to the ELISAi test, however, there were no positive results in the PCR technique. Of the diagnostic methods used in this study, the AGID test was the one that presented the best performance in the detection of reactive animals, when compared to ELISAi and PCR in blood samples and, the percentage of seropositive animals suggests a wide distribution of Brucella ovis infected sheep in the study region and could cause loss to producers.(AU)


Assuntos
Animais , Brucelose Bovina/diagnóstico , Imunodifusão/estatística & dados numéricos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Reação em Cadeia da Polimerase/estatística & dados numéricos , Sorologia
6.
Am J Infect Control ; 45(9): 964-968, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28549882

RESUMO

BACKGROUND: Several Clostridium difficile infection (CDI) surveillance programs do not specify laboratory strategies to use. We investigated the evolution in testing strategies used across Quebec, Canada, and its association with incidence rates. METHODS: Cross-sectional study of 95 hospitals by surveys conducted in 2010 and in 2013-2014. The association between testing strategies and institutional CDI incidence rates was analyzed via multivariate Poisson regressions. RESULTS: The most common assays in 2014 were toxin A/B enzyme immunoassays (EIAs) (61 institutions, 64%), glutamate dehydrogenase (GDH) EIAs (51 institutions, 53.7%), and nucleic acid amplification tests (NAATs) (34 institutions, 35.8%). The most frequent algorithm was a single-step NAAT (20 institutions, 21%). Between 2010 and 2014, 35 institutions (37%) modified their algorithm. Institutions detecting toxigenic C difficile instead of C difficile toxin increased from 14 to 37 (P < .001). Institutions detecting toxigenic C difficile had higher CDI rates (7.9 vs 6.6 per 10,000 patient days; P = .01). Institutions using single-step NAATs, GDH plus toxigenic cultures, and GDH plus cytotoxicity assays had higher CDI rates than those using an EIA-based algorithm (P < .05). CONCLUSIONS: Laboratory detection of CDI has changed since 2010. There is an association between diagnostic algorithms and CDI incidence. Mitigation strategies are warranted.


Assuntos
Clostridioides difficile/isolamento & purificação , Testes Diagnósticos de Rotina/tendências , Enterocolite Pseudomembranosa/diagnóstico , Enterocolite Pseudomembranosa/epidemiologia , Técnicas Imunoenzimáticas/estatística & dados numéricos , Reação em Cadeia da Polimerase/estatística & dados numéricos , Idoso , Proteínas de Bactérias/análise , Proteínas de Bactérias/genética , Proteínas de Bactérias/imunologia , Toxinas Bacterianas/análise , Toxinas Bacterianas/imunologia , Clostridioides difficile/genética , Clostridioides difficile/imunologia , Estudos Transversais , DNA Bacteriano/genética , Enterocolite Pseudomembranosa/microbiologia , Enterocolite Pseudomembranosa/patologia , Enterotoxinas/análise , Enterotoxinas/imunologia , Feminino , Glutamato Desidrogenase/genética , Humanos , Técnicas Imunoenzimáticas/métodos , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Reação em Cadeia da Polimerase/métodos , Quebeque/epidemiologia
7.
Cochrane Database Syst Rev ; 7: CD010502, 2016 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-27374000

RESUMO

BACKGROUND: Group A streptococcus (GAS) accounts for 20% to 40% of cases of pharyngitis in children; the remaining cases are caused by viruses. Compared with throat culture, rapid antigen detection tests (RADTs) offer diagnosis at the point of care (within five to 10 minutes). OBJECTIVES: To determine the diagnostic accuracy of RADTs for diagnosing GAS in children with pharyngitis. To assess the relative diagnostic accuracy of the two major types of RADTs (enzyme immunoassays (EIA) and optical immunoassays (OIA)) by indirect and direct comparison. SEARCH METHODS: We searched CENTRAL, MEDLINE, EMBASE, Web of Science, CDSR, DARE, MEDION and TRIP (January 1980 to July 2015). We also conducted related citations tracking via PubMed, handsearched reference lists of included studies and relevant review articles, and screened all articles citing included studies via Google Scholar. SELECTION CRITERIA: We included studies that compared RADT for GAS pharyngitis with throat culture on a blood agar plate in a microbiology laboratory in children seen in ambulatory care. DATA COLLECTION AND ANALYSIS: Two review authors independently screened titles and abstracts for relevance, assessed full texts for inclusion, and carried out data extraction and quality assessment using the QUADAS-2 tool. We used bivariate meta-analysis to estimate summary sensitivity and specificity, and to investigate heterogeneity across studies. We compared the accuracy of EIA and OIA tests using indirect and direct evidence. MAIN RESULTS: We included 98 unique studies in the review (116 test evaluations; 101,121 participants). The overall methodological quality of included studies was poor, mainly because many studies were at high risk of bias regarding patient selection and the reference standard used (in 73% and 43% of test evaluations, respectively). In studies in which all participants underwent both RADT and throat culture (105 test evaluations; 58,244 participants; median prevalence of participants with GAS was 29.5%), RADT had a summary sensitivity of 85.6%; 95% confidence interval (CI) 83.3 to 87.6 and a summary specificity of 95.4%; 95% CI 94.5 to 96.2. There was substantial heterogeneity in sensitivity across studies; specificity was more stable. There was no evidence of a trade-off between sensitivity and specificity. Heterogeneity in accuracy was not explained by study-level characteristics such as whether an enrichment broth was used before plating, mean age and clinical severity of participants, and GAS prevalence. The sensitivity of EIA and OIA tests was comparable (summary sensitivity 85.4% versus 86.2%). Sensitivity analyses showed that summary estimates of sensitivity and specificity were stable in low risk of bias studies. AUTHORS' CONCLUSIONS: In a population of 1000 children with a GAS prevalence of 30%, 43 patients with GAS will be missed. Whether or not RADT can be used as a stand-alone test to rule out GAS will depend mainly on the epidemiological context. The sensitivity of EIA and OIA tests seems comparable. RADT specificity is sufficiently high to ensure against unnecessary use of antibiotics. Based on these results, we would expect that amongst 100 children with strep throat, 86 would be correctly detected with the rapid test while 14 would be missed and not receive antibiotic treatment.


Assuntos
Antígenos de Bactérias/análise , Técnicas Imunoenzimáticas/normas , Faringite/microbiologia , Infecções Estreptocócicas/diagnóstico , Streptococcus pyogenes/imunologia , Adolescente , Criança , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Padrões de Referência , Sensibilidade e Especificidade
8.
Clin Infect Dis ; 61(8): 1293-303, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26113653

RESUMO

BACKGROUND: Aspergillus polymerase chain reaction (PCR) was excluded from the European Organisation for the Research and Treatment of Cancer/Mycoses Study Group (EORTC/MSG) definitions of invasive fungal disease because of limited standardization and validation. The definitions are being revised. METHODS: A systematic literature review was performed to identify analytical and clinical information available on inclusion of galactomannan enzyme immunoassay (GM-EIA) (2002) and ß-d-glucan (2008), providing a minimal threshold when considering PCR. Categorical parameters and statistical performance were compared. RESULTS: When incorporated, GM-EIA and ß-d-glucan sensitivities and specificities for diagnosing invasive aspergillosis were 81.6% and 91.6%, and 76.9% and 89.4%, respectively. Aspergillus PCR has similar sensitivity and specificity (76.8%-88.0% and 75.0%-94.5%, respectively) and comparable utility. Methodological recommendations and commercial PCR assays assist standardization. Although all tests have limitations, currently, PCR is the only test with independent quality control. CONCLUSIONS: We propose that there is sufficient evidence that is at least equivalent to that used to include GM-EIA and ß-d-glucan testing, and that PCR is now mature enough for inclusion in the EORTC/MSG definitions.


Assuntos
Antígenos de Fungos/análise , Aspergillus/genética , Aspergillus/isolamento & purificação , Técnicas Imunoenzimáticas , Reação em Cadeia da Polimerase , Aspergilose/diagnóstico , Aspergillus/imunologia , Galactose/análogos & derivados , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Mananas/análise , Reação em Cadeia da Polimerase/normas , Reação em Cadeia da Polimerase/estatística & dados numéricos , Controle de Qualidade , Sensibilidade e Especificidade , beta-Glucanas/análise
9.
Clin Chem Lab Med ; 51(7): 1369-83, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23370912

RESUMO

Since its inception in the mid-1980s of the 20th century testing for carbohydrate antigen 19-9 (CA 19-9) has raised expectation for an earlier diagnosis and accurate monitoring of several malignant diseases. After almost 30 years, the available evidences have confirmed the appropriateness and usefulness of determining CA 19-9 levels as a prognostic indicator and as a reliable tool for monitoring pancreatic and gastrointestinal cancer, but concerns have been raised about its applications in screening, which is actually not recommended, and in the diagnosis of malignancies, due to several interferences that limit the specificity and to the insufficient sensitivity of this marker. In this paper we aimed to review the basic concepts of CA 19-9 testing and its current applications, with a major focus on the most recent evidences dealing with assay interference, methods comparison and monitoring of malignant diseases. The prognostic value and monitoring recommendations for pancreatic, gastric and colorectal cancers are described in depth.


Assuntos
Biomarcadores Tumorais/sangue , Antígeno CA-19-9/sangue , Neoplasias Gastrointestinais/diagnóstico , Técnicas Imunoenzimáticas/normas , Neoplasias Pancreáticas/diagnóstico , Anticorpos Monoclonais , Reações Falso-Positivas , Neoplasias Gastrointestinais/sangue , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Neoplasias Pancreáticas/sangue , Radioimunoensaio/normas , Radioimunoensaio/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Forensic Sci Int ; 218(1-3): 101-5, 2012 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-22018743

RESUMO

Hair testing for drugs of abuse is performed in Lombardy by eleven analytical laboratories accredited for forensic purposes, the most frequent purposes being driving license regranting and workplace drug testing. Individuals undergoing hair testing for these purposes can choose the laboratory in which the analyses have to be carried out. The aim of our study was to perform an interlaboratory exercise in order to verify the level of standardization of hair testing for drugs of abuse in these accredited laboratories; nine out of the eleven laboratories participated in this exercise. Sixteen hair strands coming from different subjects were longitudinally divided in 3-4 aliquots and distributed to participating laboratories, which were requested to apply their routine methods. All the participants analyzed opiates (morphine and 6-acetylmorphine) and cocainics (cocaine and benzoylecgonine) while only six analyzed methadone and amphetamines (amphetamine, methamphetamine, MDMA, MDA and MDEA) and five Δ(9)-tetrahydrocannabinol (THC). The majority of the participants (seven labs) performed acidic hydrolysis to extract the drugs from the hair and analysis by GC-MS, while two labs used LC-MS/MS. Eight laboratories performed initial screening tests by Enzyme Multiplied Immunoassay Technique (EMIT), Enzyme-linked Immunosorbent Assay (ELISA) or Cloned Enzyme Donor Immunoassay (CEDIA). Results demonstrated a good qualitative performance for all the participants, since no false positive results were reported by any of them. Quantitative data were quite scattered, but less in samples with low concentrations of analytes than in those with higher concentrations. Results from this first regional interlaboratory exercise show that, on the one hand, individuals undergoing hair testing would have obtained the same qualitative results in any of the nine laboratories. On the other hand, the scatter in quantitative results could cause some inequalities if any interpretation of the data is required.


Assuntos
Cabelo/química , Laboratórios/normas , Entorpecentes/análise , Detecção do Abuso de Substâncias/normas , Cromatografia Líquida/estatística & dados numéricos , Toxicologia Forense/normas , Cromatografia Gasosa-Espectrometria de Massas/estatística & dados numéricos , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Itália , Detecção do Abuso de Substâncias/estatística & dados numéricos
11.
Kaohsiung J Med Sci ; 27(7): 258-63, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21757142

RESUMO

We evaluated the performance of a hepatitis C virus (HCV) antigen/antibody combination test [Murex HCV Antigen/Antibody Combination Test (Murex Ag/Ab test)] by comparing it with the current third-generation HCV antibody enzyme immunoassay (anti-HCV). A total of 403 serum samples were consecutively collected from four patient groups: healthy controls (n=100); HCV-infected patients (HCV group, n=102); Human immunodeficiency virus (HIV)/HCV-infected patients (HIV/HCV group, n=100); and patients with uremia (uremia group, n=101). Performances were evaluated for the Murex Ag/Ab, anti-HCV, and HCV RNA in the HIV/HCV and uremia patient groups. In the HCV group, all 102 samples showed concordant positive and negative results for anti-HCV, Murex Ag/Ab, and HCV RNA tests. In the HIV/HCV group, all 100 samples were positive for both anti-HCV and Murex Ag/Ab tests, whereas 88 patients (88%) were HCV RNA positive. In the uremia group, 14 (69.0%) of the 23 anti-HCV-positive patients were HCV RNA positive, whereas 14 (77.8%) of the 18 Murex Ag/Ab-positive patients were HCV RNA positive. None of anti-HCV-negative or Murex Ag/Ab-negative patients were HCV RNA positive. Based on the HCV RNA assay, the sensitivities for both anti-HCV and Murex Ag/Ab assays were 100%, whereas the specificities of these two assays were 89.7% and 95.4%, respectively. With good sensitivity and specificity, the Murex Ag/Ab assay could be a useful alternative diagnostic tool, especially in immunocompromised populations, such as patients with uremia or those infected with HIV.


Assuntos
Anticorpos Anti-Hepatite C/sangue , Antígenos da Hepatite C/sangue , Hepatite C/diagnóstico , Técnicas Imunoenzimáticas/estatística & dados numéricos , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Adulto , Idoso , Estudos de Casos e Controles , Feminino , HIV/crescimento & desenvolvimento , Infecções por HIV/imunologia , Infecções por HIV/virologia , Hepacivirus/imunologia , Hepatite C/imunologia , Hepatite C/virologia , Anticorpos Anti-Hepatite C/imunologia , Antígenos da Hepatite C/imunologia , Humanos , Técnicas Imunoenzimáticas/normas , Masculino , Pessoa de Meia-Idade , RNA Viral/sangue , RNA Viral/imunologia , Kit de Reagentes para Diagnóstico/normas , Sensibilidade e Especificidade , Uremia/sangue , Uremia/imunologia
12.
Acta Derm Venereol ; 91(3): 333-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21369687

RESUMO

This paper reports survey-based data on the diagnosis and management of genital herpes simplex virus (HSV) infection in 14 countries of the Eastern European Network for Sexual and Reproductive Health (EE SRH). Only 43% of the countries could provide the number of genital HSV cases recorded at national level. Eighty-six percent of countries employed syndromic management in cases of genital ulcer disease. Most countries performed type-specific and/or non-type-specific enzyme immunoassays to detect HSV antibodies. Non-type-specific serology for diagnostic purposes should be actively discouraged. Direct detection methods for HSV, such as PCR, antigen detection and culture, are available in the region, but their usage was extremely low. Their use in Eastern European countries should be actively promoted. The availability of laboratory services must be improved, and countries in the region should implement consensus recommendations for the laboratory diagnosis of genital HSV infections in order to improve clinical practice.


Assuntos
Técnicas de Laboratório Clínico/estatística & dados numéricos , Serviços de Diagnóstico/estatística & dados numéricos , Herpes Genital/diagnóstico , Simplexvirus , Virologia/métodos , Anticorpos Antivirais/sangue , Antígenos Virais/sangue , Biomarcadores/sangue , Europa (Continente)/epidemiologia , Pesquisas sobre Atenção à Saúde , Herpes Genital/epidemiologia , Herpes Genital/terapia , Herpes Genital/virologia , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Testes Obrigatórios , Reação em Cadeia da Polimerase/estatística & dados numéricos , Valor Preditivo dos Testes , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Testes Sorológicos/estatística & dados numéricos , Simplexvirus/genética , Simplexvirus/imunologia , Simplexvirus/isolamento & purificação , Inquéritos e Questionários , Virologia/estatística & dados numéricos
13.
J Clin Microbiol ; 49(2): 591-6, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21106798

RESUMO

Parasitic infection is uncommon in the United States, but surveys suggest that physicians test when the presence of parasites is unlikely and fail to order appropriate testing when suspicion is high. Numerous studies confirm that immunoassays are more sensitive for Giardia and Cryptosporidium detection, but our experience was that physicians preferentially used ovum and parasite examination (O&P). We conducted a retrospective study of fecal parasite testing at a referral laboratory nationally (1997 to 2006) and during a Cryptosporidium outbreak (Utah, 2007) to correlate physician use of O&P and enzyme immunoassays (EIAs) with the yield of parasites detected. Nationally, of 170,671 episodes, 76.0% (n = 129,732) included O&P, 27.9% (n = 47,666) included Giardia EIA, and 5.7% (n = 9,754) included Cryptosporidium EIA. Most pathogens were Giardia or Cryptosporidium. More episodes were positive when EIA was performed (n = 1,860/54,483 [3.4%]) than when O&P only was performed (n = 1,667/116,188 [1.4%]; P < 0.001), and EIA was more sensitive than O&P. However, more O&P results were positive among patients with both O&P and EIA performed (2.5%) than among those with O&P only performed (1.4%; P < 0.001), suggesting that patients tested by O&P only may have been at lower risk. During the first 10 weeks of the outbreak, physicians also preferentially used O&P over EIA, but no Cryptosporidium cases were detected by O&P. We conclude that clinicians frequently use O&P testing when test performance and epidemiology support the use of immunoassays or no testing. We recommend that stool O&P be limited to patients with negative immunoassay results and persistent symptoms or individuals at increased risk for non-Giardia, non-Cryptosporidium infection. An evidence-based algorithm for the evaluation of patients with suspected intestinal parasitic infection is proposed.


Assuntos
Técnicas Imunoenzimáticas/estatística & dados numéricos , Contagem de Ovos de Parasitas/estatística & dados numéricos , Doenças Parasitárias/diagnóstico , Parasitologia/métodos , Animais , Fezes/parasitologia , Humanos , Estudos Retrospectivos , Estados Unidos
14.
Sex Transm Dis ; 38(3): 190-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20706176

RESUMO

BACKGROUND: In 2005, syphilis screening in the Greater Toronto Area of Canada moved from the rapid plasma reagin (RPR) to a treponemal enzyme immunoassay (EIA). We sought to understand the consequences of this change on laboratory results and testing patterns with a population-based retrospective study of laboratory-based diagnoses of syphilis. METHODS: Samples positive under RPR (1998-2005) and EIA (2005-2008) screening were confirmed with an alternate treponemal test, and during the latter period underwent RPR testing. We compared monthly rates and the forecasting relationship between positives and future submissions with time-series methods, and assessed risk factors for EIA(+)/RPR(-) results using Poisson regression. RESULTS: A total of 3,092,938 submissions were included. Following EIA implementation, confirmed positive rates increased by 10.3 per 100,000 population (P<0.001). 0.59% of EIA(+)/RPR(-) individuals converted to RPR(+) within 2 months. EIA(+)/RPR(-) patients were more likely to be male (incidence rate ratio [IRR]: 2.3, 95% confidence interval [CI]: 1.6-2.5), asymptomatic (IRR: 1.8, 95% CI: 1.3-2.8), and aged>50 years (IRR: 2.4, 95% CI: 1.6-3.5) than those with EIA(+)/RPR(+) results. We detected a significant positive feedback loop between positive tests and subsequent submissions. This relationship was only transiently evident for EIA(+)/RPR(-) results up to 1 year following the changeover. CONCLUSIONS: EIA screening facilitates identification of probable latent syphilis and earlier serological detection of infectious syphilis, but may transiently cause increases in testing and indirectly suggests that physicians' interpretation of RPR(-) serology may lead to partner testing. In the absence of a true gold standard, implementation of EIA screening warrants careful communication regarding serological interpretation.


Assuntos
Técnicas Imunoenzimáticas/métodos , Programas de Rastreamento/métodos , Reaginas/sangue , Sorodiagnóstico da Sífilis/métodos , Sífilis/diagnóstico , Treponema pallidum/isolamento & purificação , Adolescente , Adulto , Criança , Feminino , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Incidência , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Ontário , Estudos Retrospectivos , Sensibilidade e Especificidade , Sífilis/sangue , Sífilis/epidemiologia , Sífilis/imunologia , Treponema pallidum/imunologia , Adulto Jovem
15.
Tsitol Genet ; 44(5): 23-30, 2010.
Artigo em Russo | MEDLINE | ID: mdl-21061689

RESUMO

Antibody responses to purified protein derivate PPD of tuberculin and to antigens MPB63 and MPB83 of Mycobacterium bovis were determined in bovine herd (94 adult animals). Statistical approach based on approximation by multiple Gaussians with Levenberg-Marquardt algorithm for analysis of antibody level distribution against antigens examined was provided. Our results confirm that indirect ELISA with recombinant MPB83 and MPB63 as well as conventional PPD could be used for test-systems development for detection of cow tuberculosis infection at the herd level.


Assuntos
Anticorpos Antibacterianos/sangue , Antígenos de Bactérias/imunologia , Doenças dos Bovinos/diagnóstico , Técnicas Imunoenzimáticas/estatística & dados numéricos , Mycobacterium bovis/imunologia , Distribuições Estatísticas , Tuberculose Bovina/diagnóstico , Animais , Bovinos , Doenças dos Bovinos/microbiologia , Técnicas Imunoenzimáticas/métodos , Proteínas Recombinantes/imunologia , Tuberculose Bovina/microbiologia
16.
Cancer Immunol Immunother ; 59(10): 1489-501, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20549207

RESUMO

No consensus has been reached on how to determine if an immune response has been detected based on raw data from an ELISPOT assay. The goal of this paper is to enable investigators to understand and readily implement currently available methods for response determination. We describe empirical and statistical approaches, identifying the strengths and limitations of each approach to allow readers to rationally select and apply a scientifically sound method appropriate to their specific laboratory setting. Five representative approaches were applied to data sets from the CIMT Immunoguiding Program and the response detection and false positive rates were compared. Simulation studies were also performed to compare empirical and statistical approaches. Based on these, we recommend the use of a non-parametric statistical test. Further, we recommend that six medium control wells or four wells each for both medium control and experimental conditions be performed to increase the sensitivity in detecting a response, that replicates with large variation in spot counts be filtered out, and that positive responses arising from experimental spot counts below the estimated limit of detection be interpreted with caution. Moreover, a web-based user interface was developed to allow easy access to the recommended statistical methods. This interface allows the user to upload data from an ELISPOT assay and obtain an output file of the binary responses.


Assuntos
Técnicas Imunoenzimáticas , Reações Falso-Positivas , Humanos , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Padrões de Referência , Sensibilidade e Especificidade
17.
Vet Immunol Immunopathol ; 134(3-4): 259-64, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19815297

RESUMO

The study of early markers for glomerular and tubular dysfunction in dogs with renal diseases holds promise to gain new insights in the pathogenesis of canine nephropathies. However, the validation of such markers in canine urine is largely lacking. Therefore, immunoassays for the quantification of a set of four urinary markers, C-reactive protein (CRP), immunoglobulin G (IgG), thromboxane B(2) (TXB(2)) and retinol binding protein (RBP), were validated by determining their sensitivity, reproducibility, precision and accuracy in a large patient group. The results show that the immunoassays are appropriate for analysis of urinary CRP, IgG, TXB(2) and RBP in dogs. Furthermore, the significant differences in urinary concentrations of the selected glomerular and tubular markers between healthy (H) dogs and dogs with several types of nephropathies (R) support their future application in both clinical settings and research models.


Assuntos
Proteína C-Reativa/urina , Cães/urina , Técnicas Imunoenzimáticas/veterinária , Imunoglobulina G/urina , Proteínas de Ligação ao Retinol/urina , Tromboxano B2/urina , Animais , Biomarcadores/urina , Estudos de Casos e Controles , Doenças do Cão/urina , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/estatística & dados numéricos , Ensaio de Imunoadsorção Enzimática/veterinária , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Rim/metabolismo , Nefropatias/urina , Nefropatias/veterinária
18.
Appl Environ Microbiol ; 76(4): 1158-67, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20038709

RESUMO

Associations between house dust-associated beta-(1,3)-glucan exposure and airway inflammatory reactions have been reported, while such exposures in early childhood have been suggested to protect against asthma and wheezing. Most epidemiological studies have used reservoir dust samples and an inhibition enzyme immunoassay (EIA) for beta-(1,3)-glucan exposure assessment. The objective of this study was to develop inexpensive but highly sensitive enzyme immunoassays to measure airborne beta-(1,3)-glucans in low-exposure environments, like homes. Specificities of available anti-beta-(1,3)-glucan antibodies were defined by direct and inhibition experiments. Three suitable antibody combinations were selected for sandwich EIAs. beta-(1,3)-Glucans in passive airborne dust collected with an electrostatic dust fall collector (EDC) and floor dust from seven homes were measured with the three EIAs. Floor dust samples were additionally analyzed in the inhibition EIA. The sandwich EIAs were sensitive enough for airborne glucan measurement and showed different specificities for commercial glucans, while the beta-(1,3)-glucan levels in house dust samples correlated strongly. The feasibility of measuring glucans in airborne dust with the recently introduced EDC method was further investigated by selecting the most suitable of the three EIAs to measure and compare beta-(1,3)-glucan levels in the EDC and in floor and actively collected airborne dust samples of the previously performed EDC validation study. The EDC beta-(1,3)-glucan levels correlated moderately with beta-(1,3)-glucans in actively collected airborne dust and floor dust samples, while the glucan levels in the airborne dust and floor dust samples did not correlate. The combination of the newly developed beta-(1,3)-glucan sandwich EIA with EDC sampling now allows assessment in large-scale population studies of exposure to airborne beta-(1,3)-glucans in homes or other low-exposure environments.


Assuntos
Poluentes Atmosféricos/análise , Poluentes Atmosféricos/imunologia , Técnicas Imunoenzimáticas/métodos , beta-Glucanas/análise , beta-Glucanas/imunologia , Microbiologia do Ar , Poluentes Atmosféricos/efeitos adversos , Poluição do Ar em Ambientes Fechados/efeitos adversos , Poluição do Ar em Ambientes Fechados/análise , Antígenos de Bactérias/análise , Antígenos de Fungos/análise , Antígenos de Plantas/análise , Asma/etiologia , Poeira/análise , Poeira/imunologia , Exposição Ambiental , Monitoramento Ambiental/métodos , Habitação , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Exposição por Inalação , Proteoglicanas , Eletricidade Estática , beta-Glucanas/efeitos adversos
19.
Am J Clin Pathol ; 132(1): 74-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19864236

RESUMO

We compared the American Society of Clinical Oncology/College of American Pathologists (ASCO/CAP) immunohistochemical scoring criterion (30%) for determining HER2 status and the Food and Drug Administration criterion (10%) with fluorescence in situ hybridization (FISH), the HER2 gene amplification method in 328 cases of breast cancer. Of 294 tumor samples successfully analyzed simultaneously by FISH and immunohistochemically, 178 of 196 cases scored 3+ using the 10% and the 30% criteria. Using FISH as the reference, the number of false-positives was reduced from 24 to 9 after application of the 30% criterion. The specificity of immunohistochemical analysis was higher with the 30% (92.0%) vs the 10% (78.8%) criterion. The kappa coefficient between FISH and immunohistochemical analysis was increased to 0.850 (almost perfect agreement; P < .001) after application of the 30% criterion vs 0.757 (substantial agreement) for the 10% criterion; the false-positive rate decreased to 5.1% from 12.2%. The chi(2) test showed that immunohistochemical analysis had significantly higher accuracy with the 30% (94.9%) vs the 10% (87.8%; P = .014) criterion. Our results from a large series of Chinese patients with breast cancer support that the ASCO/CAP 30% criterion may offer better results for assessing HER2 status.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Receptor ErbB-2/análise , Biomarcadores Tumorais/genética , Neoplasias da Mama/química , Neoplasias da Mama/genética , Carcinoma Ductal de Mama/química , Carcinoma Ductal de Mama/genética , Contagem de Células/estatística & dados numéricos , DNA de Neoplasias/análise , Feminino , Genes erbB-2 , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Hibridização in Situ Fluorescente , Valor Preditivo dos Testes , Receptor ErbB-2/genética , Reprodutibilidade dos Testes , Tamanho da Amostra , Análise Serial de Tecidos/estatística & dados numéricos
20.
Clin Vaccine Immunol ; 16(10): 1453-6, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19675225

RESUMO

Having reported that pretreatment of serum samples with EDTA at 100 degrees C improved the sensitivity for the detection of Histoplasma antigenemia, we have evaluated this method for the detection of Coccidioides antigenemia. Urine and serum samples from patients with coccidioidomycosis were tested using the MVista Coccidioides enzyme immunoassay, and serum samples with and without EDTA-heat treatment were tested. Antigenemia was detected in 28.6% of patients whose samples were not EDTA-heat treated and in 73.1% of those whose samples were treated. Antigenuria was detected in 50% of patients. Specificity of 100% was obtained in healthy subjects, but cross-reactions were seen in 22.2% of patients with histoplasmosis or blastomycosis. EDTA-heat treatment improves the sensitivity for the detection of Coccidioides antigenemia.


Assuntos
Antígenos de Fungos/sangue , Coccidioides/imunologia , Coccidioidomicose/diagnóstico , Coccidioidomicose/imunologia , Infecções Oportunistas Relacionadas com a AIDS/diagnóstico , Infecções Oportunistas Relacionadas com a AIDS/imunologia , Infecções Oportunistas Relacionadas com a AIDS/microbiologia , Complexo Antígeno-Anticorpo/sangue , Blastomicose/diagnóstico , Blastomicose/imunologia , Estudos de Casos e Controles , Coccidioidomicose/complicações , Coccidioidomicose/microbiologia , Reações Cruzadas , Ácido Edético , Histoplasmose/diagnóstico , Histoplasmose/imunologia , Temperatura Alta , Humanos , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...